<h2><u>Fluorescent Whitener Additive Compensation (FWA Compensation)</u></h2>
|
||||
<br>
|
||||
<h3>Introduction</h3>
|
||||
To make paper look "whiter" without increasing the cost of
|
||||
production, paper manufactures often employ a couple of different
|
||||
techniques. One technique is to add "shading agents" to the paper,
|
||||
that absorb a little of the middle wavelengths, thereby changing the
|
||||
color of the paper to be a little less green. By far the most
|
||||
powerful way of making the paper appear more white is to add
|
||||
Fluorescent Whitener Additive (FWA, or Optical Brightening Agents -
|
||||
OBA) to the paper. This is basically a fluorescent material that
|
||||
absorbs light at Ultra Violet (U.V.) wavelengths, and re-emits it at
|
||||
a slightly longer blue wavelengths. Subjectively something that
|
||||
appears more blue, is regarded as being "whiter".<br>
|
||||
<br>
|
||||
For more technical treatment of this topic, please refer to this
|
||||
excellent paper: <<a
|
||||
href="http://www.axiphos.com/BrightnessReview.pdf">http://www.axiphos.com/BrightnessReview.pdf</a>><br>
|
||||
<br>
|
||||
<h3>Fluorescence</h3>
|
||||
Fluorescent materials absorb light radiation at one wavelength, and
|
||||
then almost instantaneously re-emit some of that energy at a longer
|
||||
wavelength. Typical FWA absorbs wavelengths in the U.V. between
|
||||
about 300 and 400 nm, and re-emit it between 400 and 460nm. The
|
||||
visual effect of FWA depends on the amount of it present in the
|
||||
paper, and the amount of U.V. in the illumination compared to the
|
||||
level of normal, visible light. Generally better quality papers have
|
||||
lower levels of whitening agents, and cheaper papers more. <br>
|
||||
<br>
|
||||
<h3>Reflection Models and Spectro-colorimetry</h3>
|
||||
The way a spectrometer measures the effect of ink on paper, depends
|
||||
on a model of how an illuminant is reflected by the ink and the
|
||||
paper. Typically a spectrometer instrument illuminates the sample
|
||||
with a known illumination, often a incandescent tungsten lamp having
|
||||
a color temperature of 2800 degrees Kelvin. It measures the
|
||||
amount of light reflected by the sample at each wavelength, and then
|
||||
converts that to spectral reflectance value between 0 and 100% by
|
||||
dividing by it's measurement illuminant's intensity at each
|
||||
wavelength. When it comes time to use that measurement to create an
|
||||
ICC profile, the intensity of the assumed viewing illumination at
|
||||
each wavelength (typically D50 for standard ICC profiles) is then
|
||||
multiplied by the reflectance at each wavelength, and the overall
|
||||
spectral reflectance is in this way converted into CIE tri-stimulus
|
||||
values using an observer model.<br>
|
||||
<br>
|
||||
So while the instrument measures with one type of light (type A, or
|
||||
a white LED), it returns a measurement as if it had been measured
|
||||
under a different kind of light (D50) by making use of a simple
|
||||
model of light reflection off the media.<br>
|
||||
<br>
|
||||
Notice that a key assumption of this simple model is that the light
|
||||
that impinges on the sample at a given wavelength is reflected back
|
||||
at exactly the same wavelength at a diminished intensity. Notice
|
||||
also that any sort of fluorescent material (such as FWA) breaks this
|
||||
model, since fluorescent materials emit light a different
|
||||
wavelengths to which they absorb it. So the color measurements do
|
||||
not accurately portray the appearance of the media when FWA is
|
||||
present. A more complicated bi-spectral measurement (2 dimensional
|
||||
spectral reflectance) is actually needed to fully characterize
|
||||
fluorescent materials.<br>
|
||||
<br>
|
||||
<h3>What Argyll's FWA compensation does</h3>
|
||||
The FWA compensation function in Argyll improve on this simple model
|
||||
of spectral reflection by taking into account the action of FWA. To
|
||||
do this, it needs to measure the amount and nature of the FWA in the
|
||||
media, and then have enough information about the viewing
|
||||
environment to model how that FWA will behave.<br>
|
||||
<br>
|
||||
To be able to measure the level of FWA in the media, the instrument
|
||||
needs to be able to "see" the FWA in action, so the instrument needs
|
||||
to be illuminating the samples with some level of U.V. Typically all
|
||||
instruments do this, unless they have been fitted with a filter that
|
||||
filters out any U.V. illumination (so called "UV cut" instruments),
|
||||
or use an illumination source such as a "white" LED that doesn't
|
||||
emit any U.V.<br>
|
||||
Such UV excluded instruments are not suitable for use with FWA
|
||||
compensation.<br>
|
||||
The effects of FWA are modeled spectrally, so a spectral reading
|
||||
instrument is also required.<br>
|
||||
<br>
|
||||
Argyll can compute a model for the effects of FWA given the media's
|
||||
spectral characteristics, and the illuminations spectral
|
||||
characteristic, which must include the levels of U.V. in the
|
||||
illuminant. Given these two things, Argyll can calculate how much
|
||||
effect the FWA will have on the light being reflected and emitted by
|
||||
the media under the intended illumination.<br>
|
||||
<br>
|
||||
Ideally the level of FWA would be measured by comparing the paper
|
||||
spectrum with and without U.V. present in the instruments
|
||||
illumination. Because not all instruments allow these two
|
||||
measurements to be done without some sort of manual intervention,
|
||||
Argyll avoids the need for an FWA inactive (UV cut) or extra UV (UV
|
||||
LED) measurement by employing a heuristic to estimate the FWA
|
||||
inactive spectrum from the spectrum of the paper with FWA active.
|
||||
Being a heuristic, it can sometimes be fooled by certain paper
|
||||
colors into estimating more or less FWA content than is actual
|
||||
present. The heuristic works best with high quality papers with an
|
||||
essentially flat non-FWA enhanced spectrum. Papers with colored
|
||||
tints or particularly off white appearance may not work well with
|
||||
FWA compensation, unless the instrument has the capability of
|
||||
measuring with two different levels of UV.<br>
|
||||
<br>
|
||||
<img alt="Graph showing FWA effect on UV vs. UV cut measurement."
|
||||
src="FWA_measure.jpg" style="width: 387px; height: 284px;"><br>
|
||||
<br>
|
||||
Note that typically in Argyll, if a viewing illuminant is specified,
|
||||
then it is used for computing the appearance under that illumination
|
||||
(CIE XYZ values), and if FWA compensation is used, then that same
|
||||
illuminant will be assumed for the simulated measurement illuminant.
|
||||
This results in measurements that better reflects the appearance as
|
||||
the media as if it was being viewed under that illuminant, FWA
|
||||
effects and all.<br>
|
||||
<br>
|
||||
It is possible to also simulate the measurement of a media
|
||||
under one illuminant, while then computing the tristimulus values as
|
||||
if being viewed under a different illuminant, but this scenario is
|
||||
only really useful for reproducing standardized measurement
|
||||
conditions such as ISO 13655:2009 M0, M1 and M2, and is less useful
|
||||
than the normal FWA compensation scenario in modelling real world
|
||||
situations.<br>
|
||||
<br>
|
||||
[The Argyll FWA compensation algorithm is described in the paper: <font
|
||||
color="#000000"><font face="Times, serif"><font style="font-size:
|
||||
8pt;" size="1"><a
|
||||
href="http://www.imaging.org/IST/store/epub.cfm?abstrid=22190">A
|
||||
Practical Approach to Measuring and Modelling Paper
|
||||
Fluorescense for Improved Colorimetric Characterisation of
|
||||
Printing Processes", <i>Graeme W. Gill, Proc. IS&T/SID
|
||||
11th Color Imaging Conference</i></a><span
|
||||
style="font-style: normal;"><a
|
||||
href="http://www.imaging.org/IST/store/epub.cfm?abstrid=22190">,
|
||||
Scottsdale, Arizona; November 2003; p. 248-254</a><font
|
||||
size="1">, and <font size="1">w<font size="1">as f<font
|
||||
size="1">irst publi<font size="1">shed <font
|
||||
size="1">on December 2, 2002</font></font></font></font></font></font></span></font></font></font>
|
||||
in the argyllu_2002_12_02 source code. ]<br>
|
||||
<br>
|
||||
<h3>Using FWA Compensation with proofing</h3>
|
||||
The most common situation for employing FWA compensation, is in
|
||||
proofing. This is when you have one printing device, the target (say
|
||||
a printing press), and wish to emulate the behaviour of it with a
|
||||
different device, the proofer (say an inkjet printer). The aim is to
|
||||
be able to put both prints next to each other in a viewing booth,
|
||||
and have them look identical. Typically the printing process, the
|
||||
inks, and the media will be different between the target device and
|
||||
the proofer. The aim of applying color profiling is to compensate
|
||||
for these differences. Since the printing process can only darken a
|
||||
white media, the selection of the proofing stock is critical.
|
||||
Ideally it should be exactly the same color as the target, or if not
|
||||
possible, lighter, so that the proofer can tint the proofing media
|
||||
to match the target. If the two media had identical levels and types
|
||||
of FWA in them, then there would be no need to use FWA compensation,
|
||||
since the appearance of the media would match under any viewing
|
||||
condition. Typically though, the levels and types of FWA are
|
||||
different between the target paper and the proofing paper. A
|
||||
limitation imposed by tri-stimulus colorimetry is that the
|
||||
differences between the two media, inks and FWA can only be
|
||||
compensated for perfectly, under a fixed and known illuminant.<br>
|
||||
<br>
|
||||
By allowing Argyll to model the effects of FWA for both the source
|
||||
profile (the target device), and the destination profile (the
|
||||
proofing device), the effects can be accounted for, modeled
|
||||
accurately, and incorporated in the profiles, so that a subsequent
|
||||
transformation from source to destination device spaces using
|
||||
absolute colorimetric intent, achieves a (hopefully) perfect
|
||||
colorimetric reproduction. Since this is a closed system, where both
|
||||
the source and destination profiles are made for each other,
|
||||
non-standard parameters such as illuminant and observer models can
|
||||
be used, as long as they are the same for both profiles. For
|
||||
proofing, FWA should be applied identically to both profiles, by
|
||||
specifying the same illuminant, and (optionally) the same observer
|
||||
model.<br>
|
||||
<br>
|
||||
[ In practice it is possible to compensate for the color shift that
|
||||
results in viewing the media under non-D50 illumination or using a
|
||||
non 1931_2 observer, or allowing for FWA effects without severe
|
||||
incompatibility because all rendering intents except absolute
|
||||
rendering normalize to the media color, rendering the media white as
|
||||
white, even though the absolute values are not measured using a D50
|
||||
illuminant. ]<br>
|
||||
<h3>Using FWA compensation for single, general use profiles</h3>
|
||||
For creating ICC profiles that will be interchanged with other
|
||||
unknown ICC profiles, or used with non-print source or destination
|
||||
profiles, there is less flexibility, since ICC profiles by
|
||||
convention assume that all media is being viewed under D50
|
||||
illumination. The implication of this is that to be fully
|
||||
interchangeable, it's not really possible to make the profile for
|
||||
your actual viewing environment. Note that the D50 values that are
|
||||
calculated without FWA compensation do not actually reflect the
|
||||
appearance of a media under real D50, because they fail to take into
|
||||
account the different levels of FWA activity between the
|
||||
illumination using by the instrument to measure the media, and real
|
||||
D50. To allow for this and actually meet the letter of the ICC
|
||||
specifications, FWA compensation should ideally be used when
|
||||
building a interchangeable ICC profile, by selecting the D50
|
||||
illuminant, and the 1931_2 observer model (ISO 13655:2009 M1). Note
|
||||
however that unless you are interchanging with profiles made using
|
||||
M1 measurement mode data, that this is likely to make profiles <b><span
|
||||
style="text-decoration: underline;">less</span></b>
|
||||
interchangeable rather than more, since few if any profiles made
|
||||
with older instruments will represent the appearance under real D50,
|
||||
since few if any of those instruments use a real D50 illuminant that
|
||||
will trigger the correct level of FWA response, and few if any other
|
||||
packages will compensate for the differences in FWA activity between
|
||||
the instrument illuminant used and real D50 (ie. most instruments
|
||||
return M0 measurements by default, and older instruments are
|
||||
generally not capable of M1 measurement).<br>
|
||||
<br>
|
||||
Similarly, the effects of viewing the media in an environment with a
|
||||
UV filter fitted over the D50 illuminant can be simulated by using
|
||||
FWA compensation with the D50M2 illuminant, and the 1931_2 observer,
|
||||
thereby simulating the results one would get if the media had been
|
||||
measured with a "UV cut" type instrument, although such profiles are
|
||||
not technically ICC compatible.<br>
|
||||
<br>
|
||||
<h3>Measuring the illuminant</h3>
|
||||
For FWA compensation to work well, it is necessary to know what the
|
||||
spectral shape of the illuminant used for viewing is. While many
|
||||
instruments provide an illuminant measurement capability over the
|
||||
visible spectrum, for FWA compensation it is desirable to know the
|
||||
Ultra Violet (UV) component of the illuminant. Few color instruments
|
||||
are capable of reading to such short wavelengths though (the <a
|
||||
href="instruments.html#specbos">JETI specbos 1211</a> is an
|
||||
exception). Argyll provides an indirect way of estimating the UV
|
||||
component of an illuminant using its <a href="illumread.html">illumread</a>
|
||||
utility. Using illumread in combination with FWA compensation is the
|
||||
recommended approach to modelling real world appearance of paper
|
||||
containing FWA.<br>
|
||||
<br>
|
||||
<h3>FWA myths</h3>
|
||||
Amongst the user (and to some degree) vendor community, there has
|
||||
been a widely held belief that the solution to fluorescent whitener
|
||||
affecting color profiles is to simply use a UV filter fitted
|
||||
instrument. Exactly what the origin of the legend is, is hard to
|
||||
tell. Possibly it is a misinterpretation of the ANSI
|
||||
CGATS.5-1993 Annex B recommendations for measuring the impact of
|
||||
fluorescent effects, a translation of some of paper whiteness
|
||||
measurement standards into the color profiling world, or possibly in
|
||||
some common situations, if the viewing environment is very poor in
|
||||
UV, then adding a UV filter to the tungsten instrument illuminant
|
||||
makes for a better instrument/viewing illuminant match. There seems
|
||||
to be no scientific or practical basis for believing that a UV
|
||||
filter fitted instrument magically makes all FWA induced problems go
|
||||
away.<br>
|
||||
<br>
|
||||
<h3>Instrument UV filters</h3>
|
||||
Note that to be able to measure the FWA in the paper, the instrument
|
||||
has to be able to trigger Fluorescence, which it cannot do if it is
|
||||
fitted with a UV filter, or uses a light source that emits no UV
|
||||
(e.g. a normal white LED). So UV excluded instruments are not
|
||||
suitable for use with FWA compensation.<br>
|
||||