Initial commit: ArgyllCMS v3.5.0 and multichannel profiling research
This commit is contained in:
304
Argyll_V3.5.0/doc/Installing_MSWindows.html
Executable file
304
Argyll_V3.5.0/doc/Installing_MSWindows.html
Executable file
@@ -0,0 +1,304 @@
|
||||
<!DOCTYPE html PUBLIC "-//w3c//dtd html 4.0 transitional//en">
|
||||
<html>
|
||||
<head>
|
||||
<meta http-equiv="Content-Type" content="text/html;
|
||||
charset=windows-1252">
|
||||
<meta http-equiv="content-type" content="text/html;
|
||||
charset=windows-1252">
|
||||
<meta name="GENERATOR" content="Mozilla/4.73 [en] (WinNT; I)
|
||||
[Netscape]">
|
||||
<title>Argyll Installation on Microsoft Windows</title>
|
||||
</head>
|
||||
<body style="color: rgb(0, 0, 0);" vlink="#551a8b" link="#0000ee"
|
||||
alink="#ee0000">
|
||||
<h1> <u>Installing the software on Microsoft Windows<br>
|
||||
</u></h1>
|
||||
<h3 style="background-color: rgb(255, 255, 255);"><span
|
||||
style="color: rgb(51, 153, 153);">Unpacking the .zip archive:</span></h3>
|
||||
You will need to unzip the downloaded file in the location you have
|
||||
chosen to hold the executable files (perhaps somewhere like <span
|
||||
style="font-weight: bold;">\bin</span>). I would <span
|
||||
style="font-weight: bold;">NOT</span> put them in <span
|
||||
style="font-style: italic;">\Program Files</span>, since spaces in
|
||||
directory or file names and command line environments are a very bad
|
||||
mix, and will cause you endless problems. The archive will create a
|
||||
<span style="font-weight: bold;"></span> top level directory <span
|
||||
style="font-weight: bold;">Argyll_VX.X.X</span>, where X.X.X is
|
||||
the version number, and the executables will be in <span
|
||||
style="font-weight: bold;">Argyll_VX.X.X\bin</span>.
|
||||
<h3><span style="color: rgb(51, 153, 153);">Making the tools
|
||||
accessible:</span></h3>
|
||||
You should also configure your %PATH% environment variable to give
|
||||
access to the executables from your command line environment.<br>
|
||||
<br>
|
||||
For <span style="font-weight: bold;">Windows 8</span>, <b>8.1, 10
|
||||
& 11</b>, look in<br>
|
||||
<span style="font-weight: bold;"></span>Desktop
|
||||
-> Settings -> Control Panel -> System And Security ->
|
||||
System -> Advanced System Settings -> Environment Variables<br>
|
||||
<br>
|
||||
For <span style="font-weight: bold;">Windows 7</span>, look in<br>
|
||||
Start Menu -> Control Panel -> System And
|
||||
Security -> System -> Change Settings -> Advanced ->
|
||||
Environment Variables<br>
|
||||
<br>
|
||||
For <span style="font-weight: bold;">Vista</span>, look in<br>
|
||||
Start Menu -> Control Panel -> System And
|
||||
Maintenance -> System -> Change Settings -> Advanced ->
|
||||
Environment Variables<br>
|
||||
<br>
|
||||
For <span style="font-weight: bold;">XP </span>look in<br>
|
||||
Start->Settings->Control
|
||||
Panel->System->Advanced->Environment Variables<br>
|
||||
<br>
|
||||
You want to add the directory you've chosen to your %PATH%, which is
|
||||
a System Variable. Normally you would add this to the end of the
|
||||
current setting, separated by a ';'. <br>
|
||||
<br>
|
||||
So if the current value of PATH is
|
||||
"%SystemRoot%\system32;%SystemRoot%" and you unpacked Argyll version
|
||||
3.1.0 in <span style="font-weight: bold;">d:\bin\</span>, then you
|
||||
would modify PATH to be
|
||||
"%SystemRoot%\system32;%SystemRoot%;d:\bin\Argyll_V3.1.0\bin", -
|
||||
i.e. you append the path to the Argyll binaries to your PATH,
|
||||
separated by the ';' character. The change will take effect when you
|
||||
start a new command shell, which you start from Start
|
||||
Menu->Accessories->Command Prompt, or Start
|
||||
Menu->Programs->Accessories->Command Prompt. You can check
|
||||
that the environment variable has been set by running the command
|
||||
"echo %PATH%" in the command shell.<br>
|
||||
<br>
|
||||
The .zip file also contains several useful reference files (such as
|
||||
scanner chart recognition templates, sample illumination spectrum
|
||||
etc.) in the ref sub-directory, all the current documentation in a
|
||||
doc sub-directory, and instrument USB drivers in the usb directory.<br>
|
||||
<br>
|
||||
<span style="font-weight: bold;">NOTE: </span><span
|
||||
style="font-weight: bold;">Vista 64/Windows 7, 8,8.1,10 &
|
||||
11 64 bit</span> and <span style="font-weight: bold;">Beep</span>
|
||||
prompt<span style="font-weight: bold;">: </span>Microsoft (in its
|
||||
infinite wisdom) has removed the built in speaker driver, and now
|
||||
relies on systems having a sound card and speakers's installed and
|
||||
turned on to hear system beeps. So if you're wondering where the
|
||||
beeps have gone when using <a href="chartread.html">chartread</a>,
|
||||
now you know.<span style="font-weight: bold;"></span><br>
|
||||
<br>
|
||||
<span style="font-weight: bold;">NOTE: Microsofts generic VGA Driver</span>
|
||||
does not appear to support setting the graphics card VideoLUTs. You
|
||||
will need to install a display driver for your specific display
|
||||
hardware to enable this. Note also that it is possible in many cases
|
||||
to use Windows 7 video drivers on Windows 8 systems etc.. If you are
|
||||
having trouble accessing the VideoLUTs, then check in Device Manager
|
||||
that you are running the correct driver for your card, and not using
|
||||
the fallback generic driver.<br>
|
||||
<br>
|
||||
<hr style="width: 100%; height: 2px;"><br>
|
||||
<span style="font-weight: bold;">NOTE</span> that if you wish to use
|
||||
Argyll tools (<a href="dispwin.html">dispwin</a>) to control display
|
||||
calibration, that you will have to disable any other display
|
||||
calibration loader programs.<br>
|
||||
<h3><u><font color="#cc0000"><a name="BadSoftware"></a>Other
|
||||
software that may interfere with display calibration loading
|
||||
and USB instrument access:</font></u></h3>
|
||||
There are other programs that will interfere with calibration
|
||||
loading, such as igfxpers.exe that gets installed with <b>nVidia
|
||||
"Optimus"</b> technology.<br>
|
||||
You may have to disable both the igfx tray module
|
||||
(c:\windows\system32\igfxtray.exe) and the igfxpph Module
|
||||
(c:\windows\system32\igfxpph.dll) in addition to the persistence
|
||||
Module (c:\windows\system32\igfxpers.exe).<br>
|
||||
<br>
|
||||
A good tool for this is <a
|
||||
href="http://technet.microsoft.com/en-us/sysinternals/bb963902">AutoRuns</a>.
|
||||
Note that the igfxpph module may exist in several locations and you
|
||||
have to disable all of them. Reboot after changing settings.<br>
|
||||
<br>
|
||||
It has also been reported that some RGB LED driver services will
|
||||
interfere with USB instrument access. A known culprit is the <b>Logitech
|
||||
|
||||
|
||||
|
||||
LampArray Service</b> which may be have been installed with
|
||||
Logitech software or by default in <b>MSWindows 11</b>. Other <b>RGB
|
||||
|
||||
|
||||
|
||||
LED drivers</b> and services such as <b>Gigabyte RGBFusion</b>
|
||||
have also been reported as interfering with USB instrument
|
||||
access. Also reported are <b>MSI Center and SDK</b>. You may
|
||||
need to identify all such services and disable or uninstall them.<br>
|
||||
<br>
|
||||
Also reported to interfere with access to instruments, is <b>TeamSpeak3.</b>
|
||||
You may need to disable or upgrade to TeamSpeak5 to avoid issues.<br>
|
||||
Some services are reported to interfere with access to instruments,
|
||||
such as Mountain's <b>BaseCamp.Service</b>. You may need to disable
|
||||
or uninstall this service for instruments to be recognized.<br>
|
||||
<br>
|
||||
<hr style="width: 100%; height: 2px;">
|
||||
<h3><u><font color="#009900"><a name="Serial"></a>Serial
|
||||
Instruments:</font></u><br>
|
||||
</h3>
|
||||
If you are using a serial connected instrument, then there is
|
||||
nothing special to do to enable this.<br>
|
||||
<h3><font color="#ff6600"><u><a name="USB"></a>USB Instruments:</u></font></h3>
|
||||
If you are using a USB connected instrument, then suitable <span
|
||||
style="font-weight: bold;">USB system drivers</span> may need to
|
||||
be installed.<br>
|
||||
<span style="font-weight: bold;"><br>
|
||||
</span>Note that the <span style="font-weight: bold;">Huey</span>,
|
||||
<span style="font-weight: bold;">i1 Display Pro</span>, <span
|
||||
style="font-weight: bold;">ColorMunki Display</span> and <b>ColorHug</b>
|
||||
colorimeter appears as an <b>HID</b> (USB Human Interface Device
|
||||
Class) device, and hence will be assigned to the default MSWindows
|
||||
HID driver. You therefore <span style="font-weight: bold;
|
||||
text-decoration: underline;">don't need</span> to install an
|
||||
Argyll <span style="font-weight: bold;">usb</span> system driver
|
||||
for these instruments, although it is possible to select the
|
||||
libusb0.sys driver as an alternative to the default HID driver.<br>
|
||||
<br>
|
||||
If you are using the <b>JETI</b> specbos <b>1211</b><b>, </b><b>1201</b><b>,
|
||||
1511, 1501</b> and the <b>Klien K10A</b><b></b> then you may need
|
||||
to install the <a href="http://www.ftdichip.com/Drivers/VCP.htm">FTDI
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
Virtual COM Port Drivers</a> (VCP), if they are not already on
|
||||
your system. You may have to update to the latest FTDI driver to
|
||||
work with the FTDI FT231XS chip that the <b>JETI</b> specbos <b>1511,
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
1501</b> use.<br>
|
||||
<font size="+1"><u><br>
|
||||
</u></font><br>
|
||||
<br>
|
||||
<a name="libusb"></a>For all operating system versions you can
|
||||
install the ArgyllCMS libusb0.sys driver by navigating to your
|
||||
ArgyllCMS installation usb directory, and running <b>ArgyllCMS_install_USB.exe</b>.
|
||||
This will trigger a UAC prompt which you will have to agree to to
|
||||
proceed. You may have to re-plug an instrument for the new driver to
|
||||
be picked up. The driver won't be selected if you already have it
|
||||
being driver by another driver (see below).<br>
|
||||
<br>
|
||||
To uninstall the ArgyllCMS libusb0.sys driver, navigate to your
|
||||
ArgyllCMS installation usb directory, and run <b>ArgyllCMS_uninstall_USB.exe</b>.
|
||||
This will trigger a UAC prompt which you will have to agree to to
|
||||
proceed.<br>
|
||||
<br>
|
||||
If you need to update the driver because support for a new
|
||||
instrument has been added, then run <b>ArgyllCMS_uninstall_USB.exe</b>
|
||||
followed by <b>ArgyllCMS_install_USB.exe</b>.<br>
|
||||
<br>
|
||||
<span style="color: rgb(51, 153, 153); font-weight: bold;"><span
|
||||
style="color: rgb(0, 0, 0); text-decoration: underline;">Using
|
||||
Argyll drivers with existing OEM drivers:<br>
|
||||
<br>
|
||||
</span></span> If you currently have applications other than
|
||||
Argyll accessing your (non HID) USB connected instrument, then you
|
||||
will have to install the Argyll driver as above, and then switch to
|
||||
using the Argyll driver - see below for instructions on how to do
|
||||
this.<br>
|
||||
<br>
|
||||
If you are using a recent version of Microsoft Windows and want to <u>often</u>
|
||||
switch between using ArgyllCMS and the OEM driver, you can try using
|
||||
a different physical USB port for each installation, as this
|
||||
reportedly avoids the need to manually switch drivers.<br>
|
||||
<b><br>
|
||||
</b> Jump to your operating system version for the details of how to
|
||||
switch drivers:<br>
|
||||
<br>
|
||||
<a href="#WIN8">Windows 8, 8.1, 10 & 11</a><br>
|
||||
<a href="#WINV7">Windows 7</a><br>
|
||||
<a href="#WINV7">Windows Vista</a><br>
|
||||
<a href="#WINXP">Windows XP</a><br>
|
||||
<br>
|
||||
<hr style="width: 100%; height: 2px;"><a name="WIN8"></a><font
|
||||
size="+1"><span style="font-weight: bold;">Windows 8, 8.1, 10
|
||||
& 11</span></font><font size="+1"><span style="font-weight:
|
||||
bold;"></span></font><br>
|
||||
<br>
|
||||
<span style="color: rgb(51, 153, 153); font-weight: bold;"></span><span
|
||||
style="text-decoration: underline;">To switch between drivers:</span><br>
|
||||
(Plug in the instrument)<br>
|
||||
Desktop -> Settings -> Control Panel ->
|
||||
Hardware and Sound -> Device Manager<br>
|
||||
(Locate the instrument in the device list. It may
|
||||
be underneath one of the top level items.)<br>
|
||||
Right click on instrument -> Update Driver
|
||||
Software... -> let me pick from a list of device drivers on my
|
||||
computer<br>
|
||||
(Choose either the Argyll driver or another
|
||||
driver from the list)<br>
|
||||
-> Next -> Close<br>
|
||||
<br>
|
||||
<hr style="width: 100%; height: 2px;"><a name="WINV7"></a><font
|
||||
size="+1"><span style="font-weight: bold;">Windows Vista &
|
||||
Windows 7</span></font><br>
|
||||
<br>
|
||||
<span style="color: rgb(51, 153, 153);"></span><span
|
||||
style="text-decoration: underline;">To switch between drivers:</span><br>
|
||||
(Plug in the instrument)<br>
|
||||
Start -> Control Panel -> Hardware and
|
||||
Sound -> Device Manager<br>
|
||||
(Locate the instrument in the device list. It may
|
||||
be underneath one of the top level items.)<br>
|
||||
Right click on instrument -> Update Driver
|
||||
Software... -> let me pick from a list of device drivers on my
|
||||
computer<br>
|
||||
(Choose either the Argyll driver or another
|
||||
driver from the list)<br>
|
||||
-> Next -> Close<br>
|
||||
<br>
|
||||
<hr style="width: 100%; height: 2px;"><a name="WINXP"></a><font
|
||||
size="+1"><span style="font-weight: bold;">Windows XP</span></font><br>
|
||||
<br>
|
||||
<span style="color: rgb(51, 153, 153);"><span style="color: rgb(0,
|
||||
0, 0); text-decoration: underline;"></span></span><span
|
||||
style="text-decoration: underline;">To switch between drivers:</span><br>
|
||||
(Plug in the instrument)<br>
|
||||
My Computer, Right Click -> Manage ->
|
||||
Device Manager<br>
|
||||
(Locate the instrument in the device list. It may
|
||||
be underneath one of the top level items.)<br>
|
||||
Right click on instrument -> Update Driver...
|
||||
-> No, not this time -> Next<br>
|
||||
->Install from a list or specific location
|
||||
(Advanced) -> Next -> Don't search. I will choose the driver
|
||||
to install -> Next<br>
|
||||
->let me pick from a list of device drivers on
|
||||
my computer<br>
|
||||
(Choose either the Argyll driver or another
|
||||
driver from the list)<br>
|
||||
-> Next -> Finish<br>
|
||||
<br>
|
||||
<br>
|
||||
</body>
|
||||
</html>
|
||||
Reference in New Issue
Block a user