<h2 style="text-decoration: underline; font-weight: bold;">Wide
|
||||
Gamut Displays and Colorimeters<br>
|
||||
</h2>
|
||||
With the introduction of more wide color gamut displays, many people
|
||||
are finding that their Colorimeter instruments don't work so well on
|
||||
them. Why is this, and what can be done about it ?<br>
|
||||
<h3>What's the difference between a Colorimeter and a Spectrometer ?</h3>
|
||||
Colorimeters and Spectrometers both have the same aim: to measure
|
||||
tri-stimulus color values, but they go about this in two quite
|
||||
different ways.<br>
|
||||
<br>
|
||||
A spectrometer breaks the captured light up into a narrow series of
|
||||
wavelengths, measures the response at each of the wavelengths, and
|
||||
then weights and sums each wavelength response by the Standard
|
||||
Observer weighting curves, to arrive at the CIE XYZ tri-stimulus
|
||||
values. Because a Spectrometer computes the Standard Observer
|
||||
weightings in software, the accuracy of the curves is nearly
|
||||
perfect, the primary errors being due to wavelength calibration
|
||||
errors, spectrum calibration errors, and the quantised nature of the
|
||||
discrete wavelength bands.<br>
|
||||
<br>
|
||||
A Colorimeter uses physical filters that approximate the Standard
|
||||
Observer weighting curves to filter the captured light onto three
|
||||
sensors, the sensor values then<br>
|
||||
being measured, and then multiplied by a 3x3 calibration matrix to
|
||||
arrive at the CIE XYZ tri-stimulus values. The main advantage of a
|
||||
Colorimeter is its simplicity, which results in a lower cost
|
||||
instrument. In theory it is also possible to make a Colorimeter that
|
||||
cheaply captures more light by using larger sensors, but this
|
||||
possibility is rarely exploited by low cost instruments. Also due to
|
||||
cost constraints, the physical filters used in these instruments may
|
||||
not be a very good match to the CIE Standard Observer weightings,
|
||||
and if nothing were done about it, this would result in large
|
||||
measurement errors. Because such Display Colorimeters are typically
|
||||
used with additive, 3 colorant displays, it is possible to calibrate
|
||||
these errors out for any particular display, and this is the purpose
|
||||
of the 3x3 calibration matrix that is used by the instrument and/or
|
||||
instrument drivers. Since the calibration depends on the spectral
|
||||
characteristics of the display primaries, no single calibration
|
||||
matrix will be perfect for all display technologies, and typically
|
||||
the instruments will come with two matrices, one for "typical" CRT
|
||||
(Cathode Ray Tube) type displays, and one for "typical" LCD (Liquid
|
||||
Crystal) type displays. Each individual Colorimeter may have
|
||||
slightly different filters to others of the same model, due to batch
|
||||
variations in the filter material. If each Colorimeter is calibrated
|
||||
against a reference instrument, then this source of error can also
|
||||
be minimised.<br>
|
||||
<h3>Why don't Colorimeters work so well on Wide Gamut displays ?</h3>
|
||||
As explained above, due to the imperfect match between the
|
||||
Colorimeter filters and CIE Standard Observer weighting curves,
|
||||
Colorimeters have calibration matrices that are created for
|
||||
"typical" CRT or LCD displays. A Wide Gamut display by its very
|
||||
nature has primaries that have narrower spectral characteristics
|
||||
than typical displays, and this spectral difference exacerbates the
|
||||
approximations and errors in the Colorimeter filters.<br>
|
||||
<br>
|
||||
Since Spectrometers have mathematically computed weighting curves,
|
||||
they are less sensitive to the spectral characteristics of the
|
||||
display primary colors, and generally work better on Wide Gamut
|
||||
displays.<br>
|
||||
<h3>What can be done about this ?</h3>
|
||||
There are three approaches to addressing this problem:<br>
|
||||
<br>
|
||||
One is to use a Spectrometer to measure Wide Gamut displays. Since
|
||||
lower cost Spectrometers are now available (e.g. Color Munki
|
||||
Design/Photo), this may be the best general solution, since a
|
||||
Spectrometer offers a good deal more flexibility and display
|
||||
technology independence than a Colorimeter. Spectrometers are more
|
||||
expensive than colorimeters though, and typical low cost instruments
|
||||
are not well compensated for temperature changes (making reliable
|
||||
black measurement somewhat tricky), and may take longer, or be less
|
||||
accurate at measuring low light levels than the best colorimeters.<br>
|
||||
<br>
|
||||
The second approach is to correct the Colorimeter for the specific
|
||||
type of Wide Gamut Display. Often this is what has been done when a
|
||||
Colorimeter ("Puck") is supplied with a Wide Gamut display :- the
|
||||
3x3 calibration matrix inside the Colorimeter will have been "tuned"
|
||||
to match the display, or the Colorimeter driver or color management
|
||||
software will include an additional 3x3 correction matrix for that
|
||||
Colorimeter/Display combination.<br>
|
||||
<br>
|
||||
The third approach is to make a colorimeter that has filters that
|
||||
are closer to the standard observer curves, reducing the calibration
|
||||
needed for the instrument, and making it less dependent on the exact
|
||||
type of display technology. The X-Rite i1 DisplayPro, Pantone
|
||||
ColorMunki Display and possibly the Spyder 4 may have such an
|
||||
improvement. <br>
|
||||
<br>
|
||||
Argyll V1.3.0 has a facility to create and apply a <a
|
||||
href="File_Formats.html#.ccmx">correct matrix</a> to Colorimeter
|
||||
measurements. To create the correction matrix, the display, the
|
||||
Colorimeter and a reference Spectrometer are needed. (see <a
|
||||
href="ccxxmake.html">ccxxmake</a>). The correction matrix can then
|
||||
be used with the usual display measurement utilities (see <a
|
||||
href="dispcal.html#X">dispcal</a>, <a href="dispread.html#X">dispread</a>
|
||||
and <a href="spotread.html#X">spotread</a> -X option).<br>
|
||||
<br>
|
||||
Some recent colorimeters take a slightly different approach to
|
||||
calibration, and rather than using pre-defined 3x3 calibration
|
||||
matricies, they instead contain the spectral sensitivity curves for
|
||||
each particular colorimeter (e.g. i1 DisplayPro and ColorMunki
|
||||
Display, Spyder 4). It's then possible to create 3x3 calibration
|
||||
matricies automatically for any display for which the spectral
|
||||
characteristics are known. This makes it easy to tailor the
|
||||
colorimeters measurements to a particular type of display without
|
||||
having to cater for each colorimeter & display combination. <a
|
||||
href="ccxxmake.html">ccxxmake</a> also allows creation of these <a
|
||||
href="File_Formats.html#.ccss">Colorimeter Calibration Spectral
|
||||
Sample</a> files.<br>
|
||||
<br>
|
||||