<h2><b>profile/colverify</b></h2>
|
||||
<h3>Summary</h3>
|
||||
Verify a color transform by comparing CIE measurement values from
|
||||
two test charts. The charts can be any suitably formatted CGATS or <a
|
||||
href="File_Formats.html#.ti3">.ti3</a> format that contains
|
||||
corresponding XYZ, Lab or spectral values. The overall average and
|
||||
worst case delta E will be reported, as well as the worst 10% and
|
||||
best 90% of values.<br>
|
||||
<h3>Usage Summary</h3>
|
||||
<tt><small>colverify [-options] target.ti3 measured.ti3<br>
|
||||
-v
|
||||
[n]
|
||||
Verbose mode, n >= 2 print each value<br>
|
||||
-l
|
||||
|
||||
|
||||
|
||||
Match patches by sample location rather than id<br>
|
||||
-n
|
||||
Normalise
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
each files reading to white Y<br>
|
||||
-N
|
||||
Normalise
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
each files reading to white XYZ<br>
|
||||
-m
|
||||
|
||||
|
||||
|
||||
|
||||
Normalise each files reading to its white X+Y+Z<br>
|
||||
-M
|
||||
|
||||
|
||||
|
||||
|
||||
Normalise both files reading to mean white XYZ<br>
|
||||
-D
|
||||
Use
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
D50 100.0 as L*a*b* white reference<br>
|
||||
-c
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
Show CIE94 delta E values<br>
|
||||
-k
|
||||
Show CIEDE2000 delta E values<br>
|
||||
-h
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
Plot a histogram of delta E's<br>
|
||||
-s
|
||||
Sort patch value by error<br>
|
||||
-w
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
create X3DOM vector visualisation (measured.x3d.html)<br>
|
||||
</small></tt><tt><small> -W
|
||||
|
||||
create X3DOM marker & vector visualisation
|
||||
(measured.x3d.html)</small></tt><tt><br>
|
||||
</tt><tt> </tt><tt><small> -x
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
Use X3DOM axes<br>
|
||||
</small></tt><tt><small><small>-f
|
||||
[illum] Use Fluorescent
|
||||
Whitening Agent compensation [opt. simulated inst. illum.:<br>
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or
|
||||
file.sp]<br>
|
||||
-i illum
|
||||
Choose illuminant for computation of CIE XYZ from spectral
|
||||
data & FWA:<br>
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp<br>
|
||||
-o observ Choose
|
||||
CIE Observer for spectral data:<br>
|
||||
</small><small>
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
1931_2 </small><small>(def.)</small><small>, 1964_10, </small></small></tt><tt><small><small><tt><small>2015_2,
|
||||
|
||||
|
||||
2015_10, </small></tt>S&B 1955_2, shaw, J&V
|
||||
1978_2 or file.cmf<br>
|
||||
-L profile.icm Skip any first file, out of
|
||||
profile gamut patches<br>
|
||||
-X file.ccmx Apply Colorimeter
|
||||
Correction Matrix to second file<br>
|
||||
</small> <i>target.ti3</i>
|
||||
Target or reference patch data file<br>
|
||||
<i>measured.ti3</i> Measured or actual patch
|
||||
data file</small></tt><br>
|
||||
<h3>Usage Details and Discussion</h3>
|
||||
<b> colverify</b> provides a way of verifying how well a color
|
||||
transformation (such a proofing) performs.<br>
|
||||
<br>
|
||||
The <b>-v</b> flag prints out extra information during the
|
||||
checking, and prints each patch value, rather than just a summary.<br>
|
||||
<br>
|
||||
The <b>-l</b> flag makes colverify look for the SAMPLE_LOC fields
|
||||
to match patches by, rather than the default SAMPLE_ID field.<br>
|
||||
<br>
|
||||
The <b>-n</b> flag causes the two sets of values to be normalized
|
||||
to the Y value of white for each set before comparison. White is
|
||||
assumed to be the patch with the largest Y value.<br>
|
||||
<br>
|
||||
The <b>-N</b> flag causes the two sets of values to be normalized
|
||||
to the XYZ of white for each set before comparison. White is assumed
|
||||
to be the patch with the largest Y value.<br>
|
||||
<br>
|
||||
The <b>-m</b> flag causes the two sets of values to be normalized
|
||||
to the X+Y+Z of white for each set before comparison. White is
|
||||
assumed to be the patch with the largest Y value.<br>
|
||||
<br>
|
||||
The <b>-M</b> flag causes the two sets of values to be normalized
|
||||
to the average XYZ of the whites from each set before comparison.
|
||||
White is assumed to be the patch with the largest Y value.<br>
|
||||
<br>
|
||||
The <b>-D</b> flag causes the white reference point for the
|
||||
conversion to L*a*b* to be D50 with a Y value of 100%. By default
|
||||
the sample with the largest Y value is found, and the L*a*b* white
|
||||
reference scaled to have that Y value. This allows sensible delta E
|
||||
values when comparing absolute color values, such as those from
|
||||
emission or display measurements.<br>
|
||||
<br>
|
||||
The <b>-c</b> option causes the differences between the test values
|
||||
and the profile prediction of the color for each device value to be
|
||||
displayed in CIE94 delta E, rather than plain L*a*b* delta E. CIE94
|
||||
delta E has a closer correspondence with perceived color differences
|
||||
than the default CIE76 delta E values.<br>
|
||||
<br>
|
||||
The <b>-k</b> option causes the differences between the test values
|
||||
and the profile prediction of the color for each device value to be
|
||||
displayed in CIEDE2000 delta E, rather than plain L*a*b* delta E.
|
||||
CIEDE2000 delta E has a closer correspondence with perceived color
|
||||
differences than either CIE76 or CIE94 delta E values.<br>
|
||||
<br>
|
||||
The <b>-h</b> flag will display a histogram plot of the fit delta
|
||||
E's. The X scale is delta E, the Y scale is %<br>
|
||||
<br>
|
||||
If the <b>-s </b>flag is used in combination with the <b>-v</b>
|
||||
flag, then the test point by test point output will be sorted from
|
||||
worst to best.<br>
|
||||
<br>
|
||||
The <b>-w</b> creates a <a href="File_Formats.html#X3DOM">X3DOM</a>
|
||||
3D visualization of the differences between the test points in D50
|
||||
L*a*b* space, each difference being shown as a line vector. If the <span
|
||||
style="font-weight: bold;">-W</span> flag is used, then the target
|
||||
and measured values will also be marked by a small sphere. This can
|
||||
be used to visualize the placement of values in a .ti3 (or other
|
||||
CGATS file) by using the same file for both "target" and "measured"
|
||||
values.<br>
|
||||
<br>
|
||||
The <b>-x</b> flag adds Lab axes to the X3DOM output.<br>
|
||||
<br>
|
||||
The <b>-f</b> flag enables Fluorescent Whitening Agent (FWA)
|
||||
compensation. This only works if spectral data is available and, the
|
||||
instrument is not UV filtered. FWA compensation adjusts the
|
||||
spectral samples so that they appear to have been measured using an
|
||||
illuminant that has a different level of Ultra Violet to the one the
|
||||
instrument actually used in the measurement. The optional
|
||||
illumination parameter allows specifying a standard or custom
|
||||
illumination spectrum to be used as the similated instrument
|
||||
illuminant, overriding the default <b>D50</b> or CIE computation
|
||||
illuminant used for FWA (see <b>-i</b> below<b>). </b>See <a
|
||||
href="colprof.html#f">colprof -f</a> for a fuller explanation. The
|
||||
same value should be used as was used during the creation of the
|
||||
profile.<br>
|
||||
<br>
|
||||
The <b>-i</b> flag allows specifying a standard or custom
|
||||
illumination spectrum, applied to the spectral test point values to
|
||||
compute CIE tristimulus values. <b>A</b>, <b>D50</b>, <b>D50M2,
|
||||
D65</b>, <b>F5</b>, <b>F8</b>, <b>F10</b> are a selection of
|
||||
standard illuminant spectrums, with <b>D50</b> being the default.
|
||||
If a filename is specified instead, it will be assumed to be an
|
||||
Argyll specific <a href="File_Formats.html#.sp">.sp</a> spectrum
|
||||
file. If FWA compensation is used during measurement, this
|
||||
illuminant will be used by default as the simulated instrument
|
||||
illuminant. The same value should be used as was used during the
|
||||
creation of the profile.<br>
|
||||
<br>
|
||||
The <b>-o</b> flag allows specifying a tristimulus observer, and is
|
||||
used to compute PCS (Profile Connection Space) tristimulus values.
|
||||
The following choices are available:<br>
|
||||
<b> 1931_2</b> selects the standard CIE 1931 2 degree
|
||||
observer. The default.<br>
|
||||
<b>1964_10</b> selects the standard CIE 1964 10 degree
|
||||
observer.<br>
|
||||
<b> 2015_2</b> selects the standard CIE 2015 2 degree
|
||||
observer.<br>
|
||||
<b>2015_10</b> selects the standard CIE 2015 10 degree
|
||||
observer.<br>
|
||||
<b>1955_2</b> selects the Stiles and Birch 1955 2 degree
|
||||
observer<br>
|
||||
<b>1978_2 </b>selects the Judd and Voss 1978 2 degree
|
||||
observer<br>
|
||||
<b>shaw</b> selects the Shaw and Fairchild 1997 2 degree
|
||||
observer<br>
|
||||
<i><b>file.cmf</b></i> selects an observer specified by the
|
||||
given <a href="File_Formats.html#.cmf">.cmf</a> file.<br>
|
||||
<br>
|
||||
The same parameter value should be used as was used during the
|
||||
creation of the profile.<br>
|
||||
<br>
|
||||
The <b>-L</b><b> profile.icm</b> parameter causes colverify to
|
||||
ignore any patches from the first file that are out of gamut
|
||||
according to the profile given by th -L argument. This can be useful
|
||||
in evaluating accuracy without tainting it by impossible to reach
|
||||
colors.<br>
|
||||
<br>
|
||||
The <b>-X</b><b> file.ccmx</b> option applies the given 3x3
|
||||
calibration matrix to the values from the second file before doing
|
||||
any verification. This can be useful in evaluating the effects of a
|
||||
calibration matrix on raw colorimeter values, against reference
|
||||
values measured using a spectrometer.<br>
|
||||
<br>
|
||||
If both CIE and spectral values are present in the input files, the
|
||||
CIE values will be used by default. Using the <span
|
||||
style="font-weight: bold;">-i</span>, <span style="font-weight:
|
||||
bold;">-o</span> or <span style="font-weight: bold;">-f</span>
|
||||
flag will force spectral values to be used. The the <span
|
||||
style="font-weight: bold;">-i</span>, <span style="font-weight:
|
||||
bold;">-o</span> or <span style="font-weight: bold;">-f</span>
|
||||
flags will apply to both the target and measured input files.<br>
|
||||
<br>
|
||||
<br>
|
||||
<br>
|
||||
<br>
|
||||
<br>
|
||||
<br>
|
||||
</body>
|
||||
</html>
|
||||
Reference in New Issue
Block a user