<h2 style="text-decoration: underline; font-weight: bold;">About Gamma</h2>
|
||||
When calibrating display devices, the notion of "gamma value" quickly
|
||||
becomes a topic for discussion. Various numbers are often bandied about
|
||||
as if they have a well known and accepted meaning, but it turns out
|
||||
that gamma values are not a very precise way of specifying real world
|
||||
device behavior at all.<br>
|
||||
<br>
|
||||
A "gamma" curve is typically thought of as an ideal power curve, but no
|
||||
real world device has the necessary zero output at zero input to be
|
||||
able to match such a curve, and in general a display may not exactly
|
||||
reproduce an idealized power curve shape at all. The consequence of
|
||||
this is that there are countless ways of matching a real world curve
|
||||
with the ideal gamma power one, and each different method of matching
|
||||
will result in a different notional gamma value.<br>
|
||||
<br>
|
||||
Argyll's approximate specification and reading is simply the gamma of
|
||||
the ideal curve that matches the real 50% stimulus relative-to-white
|
||||
output level. I think this is a reasonable (robust and simple)
|
||||
approximation,
|
||||
because it matches the overall impression of brightness for an image. A
|
||||
more sophisticated approximation that could be adopted would be to
|
||||
locate the idea power curve that minimizes the total delta E of some
|
||||
collection of test values, but there are still many details that the
|
||||
final result will depend on, such as what distribution of test values
|
||||
should be used, what delta E measure should be used, and how can a
|
||||
delta E be computed if the colorimetric behavior of the device is not
|
||||
known ? Some approaches do things such as minimize the sum of the
|
||||
squares of the output value discrepancy for linearly sampled input
|
||||
values, and while this is mathematically elegant, it is hard to justify
|
||||
the choice of device space as the metric.<br>
|
||||
<br>
|
||||
There are many other ways in which it could be done, and any such
|
||||
approximation may have a quite different numerical value, even though
|
||||
the visual result is very similar. This is because the numerical power
|
||||
value is very sensitive to what's happening near zero, the very point
|
||||
that is non-ideal. Consider the sRGB curve for instance. It's
|
||||
technically composed of a power curve segment with a power of 2.4, but
|
||||
when combined with its linear segment near zero, has an overall curve
|
||||
best approximated by a power curve of gamma 2.2. Matching the 50%
|
||||
stimulus would result in yet another slightly different approximation
|
||||
value of about 2.224. All these different gamma values represent curves
|
||||
that are very visually similar.<br>
|
||||
<br>
|
||||
<img style="width: 400px; height: 400px;"
|
||||
alt="Plot of sRGB curve vs. power of 2.224" src="srgbplot.gif"
|
||||
align="left"><br>
|
||||
<br>
|
||||
The result of this ambiguity about what gamma values mean when applied
|
||||
to real world curves, is that it shouldn't be expected that there are
|
||||
going to be good matches between various gamma numbers, even for curves
|
||||
that are very visually similar, unless the precise method of matching
|
||||
the ideal gamma curve to the real world curve is known.<br>
|
||||
<br>
|
||||