Initial commit: ArgyllCMS v3.5.0 and multichannel profiling research
This commit is contained in:
360
Argyll_V3.5.0/doc/profcheck.html
Executable file
360
Argyll_V3.5.0/doc/profcheck.html
Executable file
@@ -0,0 +1,360 @@
|
||||
<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
|
||||
<html>
|
||||
<head>
|
||||
<title>profcheck</title>
|
||||
<meta http-equiv="content-type" content="text/html;
|
||||
charset=windows-1252">
|
||||
<meta name="author" content="Graeme Gill">
|
||||
</head>
|
||||
<body>
|
||||
<h2><b>profile/profcheck</b></h2>
|
||||
<h3>Summary</h3>
|
||||
Check an <a href="File_Formats.html#ICC">ICC</a> profile
|
||||
against <a href="File_Formats.html#.ti3">.ti3</a> test chart
|
||||
data, and optionally create a pruned .ti3 file.<br>
|
||||
<h3>Usage Summary</h3>
|
||||
<small><span style="font-family: monospace;">profcheck
|
||||
[-options] data.ti3 iccprofile.icm</span><br style="font-family:
|
||||
monospace;">
|
||||
<span style="font-family: monospace;"></span></small><small><span
|
||||
style="font-family: monospace;">-v
|
||||
[level] Verbosity level (default
|
||||
1), 2 to print each DE</span></small><small><span
|
||||
style="font-family: monospace;"></span><br style="font-family:
|
||||
monospace;">
|
||||
<span style="font-family: monospace;"> -c
|
||||
|
||||
Show
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
CIE94 delta E values</span><br style="font-family: monospace;">
|
||||
<span style="font-family: monospace;"> -k
|
||||
|
||||
Show CIEDE2000 delta E values</span><br
|
||||
style="font-family: monospace;">
|
||||
<span style="font-family: monospace;"> -w
|
||||
|
||||
create
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
X3DOM visualization (iccprofile.x3d.html)</span><br
|
||||
style="font-family: monospace;">
|
||||
<span style="font-family: monospace;"> -x
|
||||
|
||||
Use
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
X3DOM axes<br>
|
||||
-m
|
||||
Make
|
||||
X3DOM
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
lines a minimum of 0.5<br style="font-family: monospace;">
|
||||
</span><span style="font-family: monospace;"> -e
|
||||
Color
|
||||
vectors
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
acording to delta E<br>
|
||||
-s
|
||||
|
||||
|
||||
|
||||
|
||||
Sort output by delta E<br>
|
||||
-h
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
Plot a histogram of delta E's<br>
|
||||
-P
|
||||
de
|
||||
Create a pruned .ti3 with points less or equal to de delta E<br
|
||||
style="font-family: monospace;">
|
||||
</span> <span style="font-family: monospace;"> -d
|
||||
devval1,deval2,devvalN</span><br style="font-family: monospace;">
|
||||
<span style="font-family: monospace;">
|
||||
|
||||
Specify
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
a device value to sort against</span><br style="font-family:
|
||||
monospace;">
|
||||
<span style="font-family: monospace;"> -p
|
||||
|
||||
Sort
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
device value by PCS/Lab target</span><br style="font-family:
|
||||
monospace;">
|
||||
<span style="font-family: monospace;">-f
|
||||
[illum] Use Fluorescent Whitening
|
||||
Agent compensation [opt. simulated inst. illum.:<br>
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or
|
||||
file.sp]<br>
|
||||
-i illum Choose
|
||||
illuminant for computation of CIE XYZ from spectral data &
|
||||
FWA:<br>
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp</span><span
|
||||
style="font-family: monospace;"></span><br style="font-family:
|
||||
monospace;">
|
||||
<span style="font-family: monospace;"> -o
|
||||
observ Choose CIE Observer for
|
||||
spectral data:</span><br style="font-family: monospace;">
|
||||
<span style="font-family: monospace;"></span></small><small><span
|
||||
style="font-family: monospace;">
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
1931_2 </span></small><small><span style="font-family:
|
||||
monospace;">(def.)</span></small><small><span
|
||||
style="font-family: monospace;">, 1964_10, </span></small><small><span
|
||||
style="font-family: monospace;"><tt><small>2015_2, 2015_10, </small></tt>S&B
|
||||
|
||||
|
||||
1955_2, shaw, J&V 1978_2</span></small><small><span
|
||||
style="font-family: monospace;"> or file.cmf<br>
|
||||
-I intent r = relative
|
||||
colorimetric, a = absolute (default)<br style="font-family:
|
||||
monospace;">
|
||||
</span><i style="font-family: monospace;"> data.ti3</i><span
|
||||
style="font-family: monospace;">
|
||||
Test point data file</span><br style="font-family:
|
||||
monospace;">
|
||||
<i style="font-family: monospace;"> iccprofile.icm</i><span
|
||||
style="font-family: monospace;"> Profile to check</span></small>
|
||||
<br>
|
||||
<h3>Usage Details and Discussion</h3>
|
||||
<b> profcheck</b> provides a way of checking how well an <a
|
||||
href="File_Formats.html#ICC">ICC</a> profile conforms to the test
|
||||
sample data that was used to create it (or other test samples that
|
||||
are from the same device). This is the same sort of check done
|
||||
within the profile making tool (<a href="colprof.html">colprof</a>),
|
||||
but having a separate tool provides some flexibility. The
|
||||
absolute forward table in the profile is used to create PCS values
|
||||
from the sample points, and the profiles PCS value then compared to
|
||||
the PCS values of the measured sample points. Note the lower delta E
|
||||
values are not always a better measure of how good a profile is. The
|
||||
aim of a profile is to model the underlying characteristics of a
|
||||
device, not to slavishly reproduce the sampled data point values.
|
||||
Sampled data point values contain device variation and instrument
|
||||
reading inaccuracies, and a good profiler will try and filter out
|
||||
this noise, resulting in some deliberate differences between the
|
||||
profile and the sample points used to create it.<br>
|
||||
<br>
|
||||
The <b>-v</b> flag prints out extra information during the
|
||||
checking. A value greater than 1 will print the color values of each
|
||||
test point on a line. The line consists of:<br>
|
||||
<b>[</b><i>Delta_E</i><b>]</b><i> Patch_no</i><b>:</b><i>
|
||||
Device values </i><b>-></b><i> Profile PCS values </i><b>should
|
||||
|
||||
|
||||
|
||||
be</b><i> .ti3 PCS values</i><br>
|
||||
<br>
|
||||
The <b>-c</b> option causes the differences between the test values
|
||||
and the profile prediction of the color for each device value to be
|
||||
displayed in CIE94 delta E, rather than plain L*a*b* delta E. CIE94
|
||||
delta E has a closer correspondence with perceived color differences
|
||||
than the default CIE76 delta E values.<br>
|
||||
<br>
|
||||
The <b>-k</b> option causes the differences between the test values
|
||||
and the profile prediction of the color for each device value to be
|
||||
displayed in CIEDE2000 delta E, rather than plain L*a*b* delta E.
|
||||
CIEDE2000 delta E has a closer correspondence with perceived color
|
||||
differences than either CIE76 or CIE94 delta E values.<br>
|
||||
<br>
|
||||
The <b>-w</b> creates a <a href="File_Formats.html#X3DOM">X3DOM</a>
|
||||
3D visualization of the delta E's between the test points and the
|
||||
profiles prediction of the resulting colors.<br>
|
||||
<br>
|
||||
The <b>-x</b> flag adds Lab axes to the X3DOM output.<br>
|
||||
<br>
|
||||
The <b>-m</b> flag makes each error line a minimum of 0.5 delta E
|
||||
long, so that all the points are visible. This makes it easier to
|
||||
view the distribution of test points in the reference set.<br>
|
||||
<br>
|
||||
The <span style="font-weight: bold;">-e</span> flag causes the
|
||||
error vectors in the X3DOM output to be color coded according to
|
||||
their lengths, from longest to shortest: yellow, red, magenta, blue,
|
||||
cyan and green.<br>
|
||||
<br>
|
||||
The <b>-s</b> flag will cause the -v2 patch by patch delta E output
|
||||
to be sort from largest to smallest. This is useful in identifying
|
||||
badly read patches.<br>
|
||||
<br>
|
||||
The <b>-h</b> flag will display a histogram plot of the fit delta
|
||||
E's, as well as print each bin's details. The X scale is delta E,
|
||||
the Y scale is % area of each bin.<br>
|
||||
<br>
|
||||
The <b>-P N.NN</b> option will create a pruned .ti3 file called
|
||||
data_pN.NN that contains just the measurement points that have a fit
|
||||
delta E of less than or equal to the given delta E threshold. This
|
||||
can be useful if you know that there are faulty or poor accuracy
|
||||
readings in the data set. Use profcheck -h to examine the fit delta
|
||||
E histogram to choose a threshold that cuts off the tail, and then
|
||||
profcheck -P to create the pruned data set. You can check that this
|
||||
is appropriate if a profcheck -h on the resulting profile no longer
|
||||
has a long tail. <b>Note</b> that using this procedure will be of
|
||||
no benefit if the tail is due to an inherently poor fit of the
|
||||
profile to the data rather than reading inaccuracy, even if it makes
|
||||
the fit appear to be better.<br>
|
||||
<br>
|
||||
<b>NOTE</b> that the pruning does not take any special care as to
|
||||
what test points are pruned - it may prune important points such as
|
||||
<b>white</b> and <b>black</b> points!<br>
|
||||
<br>
|
||||
The <b>-d</b> parameters allow the specification of a particular
|
||||
device value, and the test point by test point output will be sorted
|
||||
by distance from the given device value. This can be useful in
|
||||
determining how well "supported" the profile is in a particular area
|
||||
of the colorspace.<br>
|
||||
<br>
|
||||
If the <b>-p </b>flag is used in combination with the <b>-d</b>
|
||||
parameters, then the test point by test point output will be sorted
|
||||
by distance in PCS (Lab) space rather than distance in device space.<br>
|
||||
<br>
|
||||
The <b>-f</b> flag enables Fluorescent Whitening Agent (FWA)
|
||||
compensation. This only works if spectral data is available and, the
|
||||
instrument is not UV filtered. FWA compensation adjusts the
|
||||
spectral samples so that they appear to have been measured using an
|
||||
illuminant that has a different level of Ultra Violet to the one the
|
||||
instrument actually used in the measurement. The optional
|
||||
illumination parameter allows specifying a standard or custom
|
||||
illumination spectrum to be used as the similated instrument
|
||||
illuminant, overriding the default <b>D50</b> or CIE computation
|
||||
illuminant used for FWA (see <b>-i</b> below<b>). </b>See <a
|
||||
href="colprof.html#f">colprof -f</a> for a fuller explanation. The
|
||||
same value should be used as was used during the creation of the
|
||||
profile.<br>
|
||||
<br>
|
||||
The <b>-i</b> flag allows specifying a standard or custom
|
||||
illumination spectrum, applied to the spectral test point values to
|
||||
compute CIE tristimulus values. <b>A</b>, <b>D50</b>, <b>D50M2,
|
||||
D65</b>, <b>F5</b>, <b>F8</b>, <b>F10</b> are a selection of
|
||||
standard illuminant spectrums, with <b>D50</b> being the default.
|
||||
If a filename is specified instead, it will be assumed to be an
|
||||
Argyll specific <a href="File_Formats.html#.sp">.sp</a> spectrum
|
||||
file. If FWA compensation is used during measurement, this
|
||||
illuminant will be used by default as the simulated instrument
|
||||
illuminant. The same value should be used as was used during the
|
||||
creation of the profile.<br>
|
||||
<br>
|
||||
<a name="o"></a> The <b>-o</b> flag allows specifying a tristimulus
|
||||
observer, and is used to compute PCS (Profile Connection Space)
|
||||
tristimulus values. The following choices are available:<br>
|
||||
<b> 1931_2</b> selects the standard CIE 1931 2 degree
|
||||
observer. The default.<br>
|
||||
<b>1964_10</b> selects the standard CIE 1964 10 degree
|
||||
observer.<br>
|
||||
<b> 2015_2</b> selects the standard CIE 2015 2 degree
|
||||
observer.<br>
|
||||
<b>2015_10</b> selects the standard CIE 2015 10 degree
|
||||
observer.<br>
|
||||
<b>1955_2</b> selects the Stiles and Birch 1955 2 degree
|
||||
observer<br>
|
||||
<b>1978_2 </b>selects the Judd and Voss 1978 2 degree
|
||||
observer<br>
|
||||
<b>shaw</b> selects the Shaw and Fairchild 1997 2 degree
|
||||
observer<br>
|
||||
<i><b>file.cmf</b></i> selects an observer specified by the
|
||||
given <a href="File_Formats.html#.cmf">.cmf</a> file.<br>
|
||||
<br>
|
||||
The same parameter value should be used as was used during the
|
||||
creation of the profile.<br>
|
||||
<br>
|
||||
The <span style="font-weight: bold;">-I</span> parameter allows
|
||||
changing the intent used in looking up the ICC profile colors to
|
||||
relative colorimetric. This would <span style="text-decoration:
|
||||
underline;">not</span> be used if you are checking a profile
|
||||
against the .ti3 file that was used to create it, since, since
|
||||
profiles are always made from absolute colorimetric measurement
|
||||
values.<br>
|
||||
<br>
|
||||
<br>
|
||||
<br>
|
||||
<br>
|
||||
<br>
|
||||
</body>
|
||||