@@ -0,0 +1,110 @@
|
||||
#ifndef HCFR_H
|
||||
|
||||
/*
|
||||
* Argyll Color Management System
|
||||
*
|
||||
* Colorimtre HCFR related defines
|
||||
*
|
||||
* Author: Graeme W. Gill
|
||||
* Date: 20/1/2007
|
||||
*
|
||||
* Copyright 2013, Graeme W. Gill
|
||||
* All rights reserved.
|
||||
*
|
||||
* This material is licenced under the GNU GENERAL PUBLIC LICENSE Version 2 or later :-
|
||||
* see the License2.txt file for licencing details.
|
||||
*/
|
||||
|
||||
/*
|
||||
If you make use of the instrument driver code here, please note
|
||||
that it is the author(s) of the code who are responsibility
|
||||
for its operation. Any problems or queries regarding driving
|
||||
instruments with the Argyll drivers, should be directed to
|
||||
the Argyll's author(s), and not to any other party.
|
||||
|
||||
If there is some instrument feature or function that you
|
||||
would like supported here, it is recommended that you
|
||||
contact Argyll's author(s) first, rather than attempt to
|
||||
modify the software yourself, if you don't have firm knowledge
|
||||
of the instrument communicate protocols. There is a chance
|
||||
that an instrument could be damaged by an incautious command
|
||||
sequence, and the instrument companies generally cannot and
|
||||
will not support developers that they have not qualified
|
||||
and agreed to support.
|
||||
*/
|
||||
|
||||
#include "inst.h"
|
||||
|
||||
#ifdef __cplusplus
|
||||
extern "C" {
|
||||
#endif
|
||||
|
||||
/* Required minimum firmware version */
|
||||
#define HCFR_FIRMWARE_MAJOR_VERSION 5
|
||||
#define HCFR_FIRMWARE_MINOR_VERSION 0
|
||||
|
||||
/* Command byte contents. (A value of 0x00 won't be tranmsitted properly) */
|
||||
/* 0xff = get firmware version */
|
||||
|
||||
|
||||
#define HCFR_MEAS_RGB 0x01 /* Enable reading RGB sensor values */
|
||||
#define HCFR_MEAS_WHITE 0x02 /* Enable reading White values */
|
||||
#define HCFR_MEAS_SENS0 0x04 /* Read sensor 0 */
|
||||
#define HCFR_MEAS_SENS1 0x08 /* Read sensor 1 */
|
||||
#define HCFR_INTERLACE_0 0x00 /* No interlace */
|
||||
#define HCFR_INTERLACE_1 0x10 /* 2 way interlace ? */
|
||||
#define HCFR_INTERLACE_2 0x20 /* 4 way interlace ?? */
|
||||
#define HCFR_INTERLACE_3 0x30 /* ? way interlace ??? */
|
||||
#define HCFR_FAST_MEASURE 0x40 /* Fast measure */
|
||||
|
||||
#define HCFR_GET_VERS 0xFF /* Get the firmware version number */
|
||||
|
||||
/* Note: update hcfr_interp_error() and hcfr_interp_code() in hcfr.c */
|
||||
/* if anything of these #defines are added or subtracted */
|
||||
|
||||
/* Fake Error codes */
|
||||
#define HCFR_INTERNAL_ERROR 0x61 /* Internal software error */
|
||||
#define HCFR_COMS_FAIL 0x62 /* Communication failure */
|
||||
#define HCFR_UNKNOWN_MODEL 0x63 /* Not an HCFR */
|
||||
#define HCFR_DATA_PARSE_ERROR 0x64 /* Read data parsing error */
|
||||
|
||||
/* Real error code */
|
||||
#define HCFR_OK 0x00
|
||||
|
||||
#define HCFR_BAD_FIRMWARE 0x01 /* Bad firmware version */
|
||||
|
||||
#define HCFR_BAD_READING 0x30 /* Error doing or parsing reading */
|
||||
|
||||
#define HCFR_CALIB_CALC 0x40 /* Error computing calibration matrix */
|
||||
|
||||
/* HCFR communication object */
|
||||
struct _hcfr {
|
||||
INST_OBJ_BASE
|
||||
|
||||
int maj, min; /* Firmware version */
|
||||
|
||||
double lcd[3][3]; /* CRT RGB->XYZ transformation matrix */
|
||||
double crt[3][3]; /* CRT RGB->XYZ transformation matrix */
|
||||
|
||||
inst_disptypesel *dtlist; /* Display Type list */
|
||||
int ndtlist; /* Number of valid dtlist entries */
|
||||
int ix; /* 0 = CRT, 1 = LCD, 2 = raw RGB from sensors */
|
||||
disptech dtech; /* Display technology enum */
|
||||
int cbid; /* current calibration base ID, 0 if not a base */
|
||||
int ucbid; /* Underlying base ID if being used for matrix, 0 othewise */
|
||||
int refrmode; /* Refresh mode (always 0) */
|
||||
double ccmat[3][3]; /* Colorimeter correction matrix */
|
||||
|
||||
inst_opt_type trig; /* Reading trigger mode */
|
||||
|
||||
}; typedef struct _hcfr hcfr;
|
||||
|
||||
/* Constructor */
|
||||
extern hcfr *new_hcfr(icoms *icom, instType itype);
|
||||
|
||||
#ifdef __cplusplus
|
||||
}
|
||||
#endif
|
||||
|
||||
#define HCFR_H
|
||||
#endif /* HCFR_H */
|
||||